Review




Structured Review

Narishige inc micro manipulator
Micro Manipulator, supplied by Narishige inc, used in various techniques. Bioz Stars score: 97/100, based on 5223 PubMed citations. ZERO BIAS - scores, article reviews, protocol conditions and more
https://www.bioz.com/product/micro+manipulator/Micromanipulator/bio_rxiv__64898__2026__04__02__716240-164-6-8
Average 97 stars, based on 5223 article reviews
micro manipulator - by Bioz Stars, 2026-10
97/100 stars

Images

Related Articles

other:

Article Title: Stress-induced reduction of sodium leak currents causes social deficits by impairing dorsal dentate gyrus-medial septum glutamatergic projection.
Article Snippet: Stress-induced social deficits are related with the malfunction of dentate gyrus (DG).. However, the exact molecular mechanism and/ or neural circuit of DG participated in social impairments induced by chronic stress is not fully known.. Here, we report that the sodium leak channel (NALCN) reduction in the dorsal DG (dDG) but not the ventral DG (vDG) induces social deficits of chronic stress through lowering the excitability and the firings of the glutamatergic neurons.

Article Title: Spatiotemporal organization of dynein in bulk cytoplasm promotes aster growth and positioning in large embryos
Article Snippet: Needles were manually controlled using a micro-manipulator (MN-153, Narishige) on the stage of a stereomicroscope (Leica M80).

Article Title: Large-scale investigation confirms TRPM3 ion channel dysfunction in Myalgic Encephalomyelitis/Chronic Fatigue Syndrome
Article Snippet: Other equipment included in the experiment set-up are CV203BU head-stage (Molecular Devices, Sunnyvale, CA, USA), a three-way coarse manipulator, micro-manipulator (Narishige, Tokyo, Japan (NCNED) and from Sutter Instruments CA, USA (UWA)), and Axopatch 200B amplifier.

Article Title: Viral contamination and reproductive outcome of testicular tissue samples from HIV-positive men: a retrospective single-center case series report.
Article Snippet: Purpose To evaluate (1) HIV-1 viral load in preand post-processed testicular tissue samples from virally suppressed azoospermic HIV-positive men and (2) the reproductive outcome of the subsequent ICSI cycles.. Methods This single-center case series reports on all virally suppressed HIV-positive men who underwent testicular biopsy at our center between 2015 and 2023.. Whenever spermatozoa were present, samples underwent washing and viral load assessment in the first and last supernatant fractions.

Microelectrode Array:

Article Title: Asymmetric neuromodulation in the respiratory network contributes to rhythm and pattern generation
Article Snippet: .. Using a micro-manipulator (Narishige MMN-33), we slowly inserted the MEA into the brainstem until we observed an ensemble of neuronal activities with respiratory-related firing patterns. ..

Transferring:

Article Title: Low‐Dose naltrexone restored TRPM3 ion channel function in natural killer cells from long COVID patients
Article Snippet: In this study, glass pipettes were pulled using borosilicate glass capillaries (Harvard Apparatus, Holliston, MA, United States, GC150F-15, outside diameter = 1.5 mm, inside diameter = 0.86 mm) and polished immediately before use. .. Pipette resistance was 8–12 MΩ, and we used a CV203BU head-stage (Molecular Devices, Sunnyvale, CA, United States) connected to a 3-way coarse manipulator and a micro-manipulator (Narishige, Tokyo, Japan). .. An Axopatch 200B amplifier and pClamp 10.7 software (Molecular Devices, Sunnyvale, CA, United States) were used to amplify and record electrical signals, with data filtered at 5 kHz and sampled digitally at 10 kHz via a Digidata 1440A analog-to-digital converter (Molecular Devices, Sunnyvale, CA, United States).

Article Title: Growth Differentiation Factor 15 Induces Gastric Fundus Contraction Involving Cholinergic Excitation: Morphofunctional Evidence in Rodent Models
Article Snippet: .. The patch pipette was inserted in a CV203BU head‐stage (Axon Instruments, Foster City, CA) attached to a three‐way coarse manipulator and micro‐manipulator (Narishige, Tokyo, Japan) and an Axopatch 200 B amplifier (Axon Instruments, Foster City, CA) as previously described [ ]. .. The generation of current‐ and voltage‐clamp protocols as well as data acquisition were accomplished by the A/D‐D/A interfaces (Digidata 1200; Axon Instruments) and Pclamp 6 software (Axon Instruments Foster City, CA).

Article Title: Dendritic retraction contributes to spine density recovery following denervation in vitro.
Article Snippet: Local injections into the dentate gyrus (AAV2-hSyn-tdTomato) or the entorhinal cortex (AAV2-hSyn-EGFP) were performed with injection pipettes pulled from thin-walled borosilicate capillaries (Harvard Apparatus, 30-0066) using a DMZUniversal Puller (Zeitz-Instrumente). .. Pipettes were held by a microJECT pipette holder with built-in valve (npi electronic) and positioned using a micro-manipulator (Luigs and Neumann). .. Undiluted solutions of AAV2-hSyn-tdTomato or AAV2-hSyn-EGFP were injected directly into the suprapyramidal blade of the dentate gyrus or into the medial part of the entorhinal cortex, respectively, using a pressure application system (PDES-01DXH, npi electronic).



Similar Products

93
Siskiyou Corporation four axis micro manipulator
Four Axis Micro Manipulator, supplied by Siskiyou Corporation, used in various techniques. Bioz Stars score: 93/100, based on 1 PubMed citations. ZERO BIAS - scores, article reviews, protocol conditions and more
https://www.bioz.com/product/micro+manipulator/Motorized+manipulator%2C+4-axis%2C+base+mount+with+round+clamp/bio_rxiv__64898__2026__08__06__743316-151-1-9
Average 93 stars, based on 1 article reviews
four axis micro manipulator - by Bioz Stars, 2026-10
93/100 stars
  Buy from Supplier

97
Narishige inc micro manipulator
Micro Manipulator, supplied by Narishige inc, used in various techniques. Bioz Stars score: 97/100, based on 1 PubMed citations. ZERO BIAS - scores, article reviews, protocol conditions and more
https://www.bioz.com/product/micro+manipulator/Micromanipulator/bio_rxiv__64898__2026__04__02__716240-164-6-8
Average 97 stars, based on 1 article reviews
micro manipulator - by Bioz Stars, 2026-10
97/100 stars
  Buy from Supplier

99
Eppendorf AG cell tram oil micro manipulator
Cell Tram Oil Micro Manipulator, supplied by Eppendorf AG, used in various techniques. Bioz Stars score: 99/100, based on 1 PubMed citations. ZERO BIAS - scores, article reviews, protocol conditions and more
https://www.bioz.com/product/micro+manipulator/Eppendorf/pm41820353-370-8-12
Average 99 stars, based on 1 article reviews
cell tram oil micro manipulator - by Bioz Stars, 2026-10
99/100 stars
  Buy from Supplier

97
Narishige inc oil driven micro manipulator
Oil Driven Micro Manipulator, supplied by Narishige inc, used in various techniques. Bioz Stars score: 97/100, based on 1 PubMed citations. ZERO BIAS - scores, article reviews, protocol conditions and more
https://www.bioz.com/product/micro+manipulator/Micromanipulator/pmc13019782-260-6-9
Average 97 stars, based on 1 article reviews
oil driven micro manipulator - by Bioz Stars, 2026-10
97/100 stars
  Buy from Supplier

99
Eppendorf AG micro manipulators
Micro Manipulators, supplied by Eppendorf AG, used in various techniques. Bioz Stars score: 99/100, based on 1 PubMed citations. ZERO BIAS - scores, article reviews, protocol conditions and more
https://www.bioz.com/product/micro+manipulator/Eppendorf/pm41351216-242-0-1
Average 99 stars, based on 1 article reviews
micro manipulators - by Bioz Stars, 2026-10
99/100 stars
  Buy from Supplier

97
Narishige inc narishige micro manipulator
Narishige Micro Manipulator, supplied by Narishige inc, used in various techniques. Bioz Stars score: 97/100, based on 1 PubMed citations. ZERO BIAS - scores, article reviews, protocol conditions and more
https://www.bioz.com/product/micro+manipulator/Micromanipulator/pmc12863336-275-12-12
Average 97 stars, based on 1 article reviews
narishige micro manipulator - by Bioz Stars, 2026-10
97/100 stars
  Buy from Supplier

Image Search Results